Fire Watch Glossary
The terms these guides use, in plain words. Each links back to the guide that covers it in depth where one exists.
AHJ (authority having jurisdiction)
The official or agency with legal power over your building or operation, usually the fire marshal or fire code official. When a rule says approved, it means approved by them.
Approved fire watch
A fire watch acceptable to the AHJ: the people, the interval, and the record all subject to their acceptance.
Compensatory measure
Anything that offsets lost protection during an impairment: a fire watch, temporary detection, curtailed hazardous work. Common in healthcare and military usage.
Defend-in-place
The strategy of protecting occupants where they are, with compartments and systems, instead of evacuating. The healthcare model.
Evacuate-or-watch fork
The choice the major impairment rules force once a required system is out beyond tolerance: empty the affected areas or post an approved fire watch.
Fire code official
The IFC’s term for the enforcing official; the person the code means when it says where required by.
Fire watch
One or more trained people assigned to patrol for fire, notify the fire department and occupants, and keep a record, while normal protection is impaired or a hazard demands it.
Hot work
Welding, cutting, torch work, grinding: any work producing sparks, flame, or enough heat to ignite nearby material.
ILSM (interim life safety measures)
The accreditor version of impairment management in healthcare: assessed, documented compensating steps while life safety is degraded.
Impairment
Any period a required fire protection system, or part of one, is out of service. Preplanned or emergency.
Impairment coordinator
The named person who runs the impairment: notifications, tag, mitigation, restoration.
Incipient fire
A fire in its beginning stage, small enough to knock down safely with a portable extinguisher. The outer limit of a guard’s firefighting.
K-tags
CMS survey deficiency tags for life safety findings in certified healthcare facilities.
Marine Chemist
The certificated professional who tests vessel spaces and issues the certificate that clears hot work near spaces that held flammables.
PASS
Pull, aim, squeeze, sweep: the extinguisher technique, used only after the alarm is raised and only on incipient fires.
PEEP (personal emergency evacuation plan)
The individual plan for an occupant who needs help evacuating: who helps, by what route, with what equipment.
Post orders
The written instructions a specific watch runs on: route, interval, contacts, log format, and the authorities behind them.
Red Tag
The best-known carrier impairment permit system, associated with FM: notification, tag, precautions, close-out.
Supervisory signal
An alarm system’s report of an off-normal condition, a moved valve, low air, a pump issue. Investigate what caused it and whether protection is impaired.
The 35-foot rule
The hot work discipline from the general industry and shipyard rules and NFPA 51B: combustibles within 35 feet get moved, shielded, or watched.
The 4-hour clock
The common adopted threshold for fire alarm outages: more than 4 cumulative hours in 24 in an occupied building brings the evacuate-or-watch decision.
The 10-hour clock
The common adopted threshold for sprinkler outages: more than 10 hours in 24, evacuate the affected areas or post the watch.